0769-82327388
文章來源 : 廣東優(yōu)科檢測 發(fā)表時間:2022-10-25 瀏覽數(shù)量:
Dielectric Voltage-Withstand Test是UL817標(biāo)準(zhǔn)中的一個試驗項目,意思是絕緣耐壓測試。美規(guī)軟線組件和電源軟線UL817認(rèn)證需要進行絕緣耐壓測試,接下來為大家介紹UL817絕緣耐壓測試。
依據(jù)標(biāo)準(zhǔn):
UL817 (104.1 – 104.6)
測試對象:
電源線及電線組件
樣品數(shù)量:
Normal: 13 條
Tightened: 20 條
Reduced: 5 條
測試方法:
在電源線或電線組件的載流線之間以及載流線與地線之間按下述任意一種方式測試:
a) 1250V 交流 (40 – 70Hz), 1 分鐘;
b) 1500V 交流 (40 – 70Hz), 1 秒鐘;
c) 1770V 直流, 1 分鐘;
d) 2100V 直流, 1 秒鐘。
判定:
任何兩根線間不能承受上述的測試均為不合格。
Dielectric Voltage-Withstand Test
104.1 Each cord set and power-supply cord shall be capable of withstanding without electrical breakdown,as a routine production line test,the application of a test potential between line conductors and between each line conductor and grounding conductor,if provided,using one of the following methods.
a) A1250Va-c(40-70Hz) test potential applied for 1 minute,
b) A1500Va-c(40-70Hz) test potential applied for 1 second,
c) A1770Vd-c test potential applied for 1 minute,or
d) A2100Vd-c test potential applied for 1 second.
104.1 每一組電線和電源線應(yīng)能承受不發(fā)生電擊穿的情況,作為常規(guī)的生產(chǎn)線測試,使用下列方法之一,在導(dǎo)線之間和導(dǎo)線與接地導(dǎo)體之間施加測試電位。
a) A1250Va-c(40-70Hz)試驗電勢施加1分鐘,
b) A1500Va-c(40-70Hz)試驗電勢施加1秒,
c) A1770Vd-c試驗電勢施加1分鐘,或
d) A2100Vd-c試驗電勢施加1秒。
104.2 The test potential maybe gradually increased to the required value but the full value is to be applied for 1 second or 1 minute as required.
104.2 測試電位可能會逐漸增加到所需值,但應(yīng)根據(jù)需要應(yīng)用全部值1秒或1分鐘。
104.3 The test equipment for a-c testing shall include a transformer having an essentially sinusoidal output.
104.3 用于交流測試的測試設(shè)備應(yīng)包括具有基本正弦輸出的變壓器。
104.4 lf the output of the test equipment power-supply is less than 500VA,the equipment shall include a voltmeter in the output circuit to directly indicate the test potential,and an audible or visual indication of breakdown.In the event of breakdown,manual reset of an external switch is required or an automatic reject of the unit under test is to result.
104.4 如果測試設(shè)備電源的輸出小于500VA,設(shè)備應(yīng)在輸出電路中包括電壓表,以直接指示測試電位,并發(fā)出擊穿的聽覺或視覺指示。在發(fā)生故障時,需要手動復(fù)位外部開關(guān)或自動拒絕被測單元的結(jié)果。
104.5 If the output of the test equipment power-supply is500VAor larger,the test potential maybe indicated by a voltmeter in the primary circuit or in a tertiary winding circuit,by a selector switch marked to indicate the test potential,or by a marking in a readily visible location to indicate the test potential of equipment having a single test potential output.When marking is used without an indicating voltmeter,the equipment shall include a positive means such as a power-on lamp to indicate that the manual reset switch has been reset following a trip out.In the event of breakdown,manual reset of an external switch SW is required or an automatic reject of the unit under test is to result.
104.5 如果測試設(shè)備電源的輸出大于500VA或更大,則測試電位可能由初級電路或三級繞組中的電壓表指示,通過標(biāo)記的選擇開關(guān)來指示測試電位,或通過在容易看到的位置標(biāo)記來指示測試電位的設(shè)備具有單一的測試電位輸出。當(dāng)在沒有指示電壓表的情況下使用標(biāo)記時,設(shè)備應(yīng)包括一個正向裝置,例如上電燈,以指示手動復(fù)位開關(guān)在跳閘后已復(fù)位。如果發(fā)生故障,需要手動復(fù)位外部開關(guān)軟件,否則將導(dǎo)致被測單元的自動拒絕。
104.6 Test equipment other than that described in 104.3-104.5 maybe used if found to accomplish the intended factory control.
104.6 除104.3-104.5所述設(shè)備外的測試設(shè)備,如果發(fā)現(xiàn)用于完成預(yù)期的工廠控制,則可以使用。
優(yōu)科檢測認(rèn)證是獲得UL TPTDP免目擊測試實驗室授權(quán)的第三方UL檢測實驗室,實驗室具備UL817標(biāo)準(zhǔn)全項測試能力,可提供軟線組件和電源軟線UL817測試及UL認(rèn)證服務(wù)。